Kongskilde MULTIAIR FC 3000 Manual Del Operador página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Connection of the blower:
1 - remove blower covers screws on both sides, and
lift away both covers. Remove the 4 screws holding
the upper panel in place, loosen the drain hoses at the
bottom support, and remove the upper panel. If neces-
sary, push down the panel to release it from the side
enclosures.
2 - the cable relief unions are loosened. The power
supply and thermistor cables are guided through the
bottom plate of the blower.
3 - the motor connection box lid is removed, and the
thermistor cable is guided through the cable relief union
as shown.
4 - the thermistor cable is connected into the terminals
(push down the bushings), and the cable relief re-tight-
ened.
5 - the power supply cable is guided through the cable
relief, and the relief ring installed as shown.
6 - make sure the cable is seated as shown.
3
Tabla de contenido

Solución de problemas

loading

Tabla de contenido