Failure to start cooking fan motor
Irregular electronic control
If Start is pressed immediately the
alarm buzzes:
Brn BLOC
The oven fails to reach the Set Point
but always goes over 20°
Damaged condenser
Electronic board damaged
Keyboard fault
The Reset signal from the electronic
board relay SC1 fails to reach the CF
control flame
SCI electronic board damaged
CF Flame control damaged
Gas valve output pressure
unregulated
Side panels excessively low
Reset for the wrong gas type
Wrong gas supply pressure
UK/24
Replace the condenser
Replace the electronic board
Replace keyboard
Ensure that all connections from the
SC1 circuit board to the CF flame
control are effective and that there are
no damaged cables
Replace the SCI electronic board
Replace the CF flame control
Check that the output pressure from
the valve is 0 otherwise adjust; if it
fails to adjust, replace the valve
Lift the side panels
Check that the oven is regulated
properly for the type of gas power
supply and the outgoing pressure
from the valve gas is 0 mbar.
Ensure that gas and supply pressure
are set as shown in TAB. 1 of the
instruction manual (for your country)