Bosch Nexxt 100 Serie Manual De Instrucciones página 5

Idiomas disponibles

Idiomas disponibles

Check the dryer for transportation
damage. Do not connect a dryer which
is visibly damaged. If in doubt, contact
your dealer.
Supplied
components
For U.S.A.
The dryer is supplied without
a power cord. Thepower
cord
must be connectedby
qualified
persons only.
After removing the packaging,
immediately
remove any objects
from the drum.
The dryer is delivered as a complete
unit. The operating instructions and
supplied accessories can be found in
the drum.
Installation
location
Do not install the dryer:
-
outdoors
-
in an environment with dripping
water,
-
near flammable materials,
-
in rooms which are at risk of frost,
-
in rooms which may contain gas
or other fuels,
-
in cupboards with Iockable doors
or in alcoves.
The installation room must be well
ventilated, otherwise the dryer will
operate below optimum performance.
Do not operate the dryer at
temperatures above 104°F (40°C) and
below 41 °F (5°C). Low temperatures
affect the automatic program sequence
and may prolong the drying times.
The installation surface for the dryer
must be clean, level and firm. Do not
install the appliance on carpets!
Compensate for uneven floors with the
height-adjustable feet.
Install the dryer and level side to side
and front to back. Use a bubble level.
Never remove the height-adjustable
feet!
The size of the installation area
depends on the dimensions of the
dryer. Ensure that there is adequate
room for the swivel range of the door!
a
Dimension
Weight
a
27.0" (686 mm)
125 Ibs
b
31.8" (808 mm)
(56 kg)
with
c
37.2" (945 mm)
packaging
d
19.7" (500 mm)/
143 Ibs
angle
170 - 180°
(64 kg)
If installing the dryer in a closet, observe
the minimum distances according to
the following table:
Minimum Installation Clearances
Closet
Sides
0" (0 mm)
Top
12" (305 ram)
Real*
0" (0 mm)
* as closeto wallas ventingwill allow.
Important information concerning
minimum distances:
-
Depending on the location of the
exhaust air connection, an
additional minimum distance of
5 _&inch (14 cm) must be provided
on this side for pipes/brackets (see
page 7),
-
Distances above the indicated
minimum dimensions reduce the
risk of mold formation behind the
appliance.
-
Additional distances reduce noise
transmission.
-
Additional distances facilitate
installation and service.
-
If the dryer is installed in a small
room, the doors of the room must
be fitted with vents of a specified
minimum size.
The dryer door is delivered with hinges
on the right. If required, the door hinges
can be switched to the left side.
If the door hinges are to be changed
over, please contact your dealer or our
customer service-team
(see page 20)
Electrical
connection
Power cord must be connected
by a qualified person only.
Connect to individual
Branch
Circuit.
Do not use an adapter.
Do not use an extension
cord.
Do not remove ground prong.
For CANADA
Your dryer comes with a power supply
cord, CSA listed in Canada.
The Bosch dryer requires a 4-wire
receptacle.
When installing the receptacle for the
dryer cord, ensure that the power
supply cord is accessible when the
dryer is in the installed position.
loading

Este manual también es adecuado para:

Wtmc1301usWtmc1301cn