Electrical Connection - Bosch Nexxt WTMC3300US/01 Operacion, Cuidado E Instrucciones Para La Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electrical
connection
Power cord must be connected
by a qualified
person only.
Connect
to individual
Branch
Circuit.
Do not use an adapter.
Do not use an extension
cord,
Do not remove ground prong,
For CANADA
Your dryer comes with a power
supply cord, CSA listed in Canada,
The Bosch dryer requires a 4-wire
receptacle,
When installing the receptacle
for
the dryer cord, ensure that [he
power supply cord is accessible
when the dryer is in the installed
position,
The power cord should only be
replaced
by a qualified person.
Use a 4_wire power supply cord
(see electrical
connection
U,S,A,
below).
For U.S.A.
Your dryer comes without a power
supply cord. The power cord must
meet the following
requirements:
UL listed in Ihe USA
208 - 240 volt rated (minimum)
30 amps
Type SRDT or DRT (UL 2t58)
Five feet long (minimum)
Power cord mus[ be connected
by a licensed electrician
only,
Use only a U.L approved
30 amp power cord with strain
relief clamp -
note manufacturer's
instructions.
Do not plug end of power cord
into a live receptacle
before con-
necting power cord Io appliance
IerminaIs and dosing junction/
spliIter box as described
below,
Do not reuse old power cord.
Cord must have dosed
loop or
upturned
end wire terminaIing
connectors.
Do not make a sharp bend or
crimp wiring/conductor
at con-
nectbns,
Only a 4-conductor
cord shall
be used when the appliance
is
installed in a mobile home, in a
recreational
vehicle, in a new
branch circuit installation
or an
area where lhe local codes do
not permi[ grounding
through
the neutral.
Connecting
4-wire
power
supply
cord
1. Remove [he screws from the
cover of the terminal block
located at the top rear of the
appliance.
IPEt--_0
_
_
2
1
terminalblock
2
groundingslrap
3
Anglebracketfor strainreliefclamp
2. Loosen the bottom
screw of
the grounding
strap. Place the
screw to the GROUND
IocaIion. StraighIen
the
grounding
sIrap and hang
loosely.
3. Fix [he strain relief clamp to [he
angle bracket,
Tighten [he nut.
1
4. Loosen the 2 screws labeled L
and the screw labeled N in [he
terminal block, and the screw
of the GROUND terminal.
5. Thread the 4 wire cable through
the U.L, strain relief clamp.
6. Tighten the screws (2,5 Nm) of
the U.L, strain relief clamp so
that the power cord cannot be
moved.
7. Attach the power cord ground
conductor
(green) to the
GROUND
terminal. Tighten the
screw (2,5 Nm) so that the
ground conductor
is held
securely
in place.
8. Attach the 2 power cord outer
conductors
(red and black) to
the 2 terminals
labeled L and
the remaining
power cord
conductor
(white) to [he
terminal labeled N,
9. Tighten all 3 screws (3 Nm) so
that the power conductors
are
held securely in place,
Tabla de contenido
loading

Tabla de contenido