Top/Bottom Installation Configuration; Electronic Configuration For Lower Or Upper Wall Installations; Use; Warnings - Olimpia splendid Unico Air 10 SF EVA Instrucciones Para El Uso Y El Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 191

2.5 - TOP/BOTTOM INSTALLATION CONFIGURATION

The unit can be installed both in the lower part (adjacent to the floor) and in the upper
part (adjacent to the ceiling) of the wall.
Depending on installation (ceiling or floor) it is sufficient to change the electronic
configuration so as to optimize the aperture angles of the air outlet flap.
2.5.1 - E lectronic configuration for lower or upper wall installations
Work as follows (see fig. 30):
a.
Insert the plug in the power socket to power the
air conditioner, then make sure it is switched
to stand-by mode.
b.
Check that all the LEDs on the display are off;
press and hold down the H button, when an
acoustic signal sounds, release the button.
To configure the unit for
c.
wall-mounted installation
at the top, press button H,
LED C (yellow) will light up.
To configure the unit for
d.
bottom wall installation,
press button H again, LED
D (green) will light up.
e.
Wait a few seconds until the standby mode is restored and check that all the
LEDs on the display are off before starting the unit.
During the configuration phases point (c) and point (d) the LED D
(green) and the LED A (red) will also light up.
3 -

USE

3.1 - WARNINGS

The installation and electrical connection of the air conditioner
should be carried out by specialized personnel who possess the
requisites set forth by law.
The installation instructions are contained in the appropriate par-
agraph of this manual.
EN - 26
30
G
LED D
LED C
LED B
H
LED A
Tabla de contenido
loading

Tabla de contenido