Alarm message
MOTOR PAUSE
TRACTION PAUSE!
BRUSHES CURRENT
BATTERY RESERVE
BATTERY DOWN
BATTERY FLAT
WORN BRUSHES
BRAKE
ALARMS/WARNINGS DISPLAYED
Machine behaviour
Drive stops
Drive stops
A simple warning that the
battery charge is low
The machine's functions
are stopped, excluding
drive
The machine stops
The machine continues
working
The parking brake is
engaged
Description of the problem
Drive motor
overtemperature > 95°C.
Electronic control circuit
overtemperature > 85°C
Excess current or centre
brush blocked
Shown when the battery
voltage falls below 21.3V
If the voltage read falls
below 20.3V for 3 seconds
consecutively
If the voltage read falls
below 18V for 3 seconds
consecutively
Brush no longer able to
due to excessive wear
EN
Possible solution
After climbing a gradient
this can be quite normal;
wait 20 minutes for the
motor to cool down.
Check that the brake is not
locked.
Check that the front wheel
turns freely.
If the ambient temperature
is high, stop the machine
and wait 20 minutes
before restarting. If the
problem remains, contact
a service centre.
Check free brush
movement or for
the presence of any
impediments (ropes,
plastic and so on)
No action needed, except
to charge the battery
Charge the battery
Charge the battery
Replace the centre brush
Release the parking brake.
29