Periodic checks
CHECK
BATTERY ELECTROLYTE LEVEL
CHECK THE BRUSHES (OR CARBON BRUSHES) ON ALL
OF THE ELECTRIC MOTORS AND REPLACE IF WORN
BELT WEAR
BRAKE ADJUSTMENT
TIGHTNESS OF THE NUTS AND SCREWS
EXTENT OF WEAR ON SIDE BRUSH
CLEANING SUCTION MOTOR AIR FILTER
TIGHTNESS OF SEALS /FLAP
(*) To be performed by trained service personnel only
PERIODS OF INACTIVITY
If the machine is not used for some time, for example, on
display in a showroom or stored in the warehouse for a
period of more than one month, the following operations
are required:
-
Recharge the batteries completely. During long
periods of inactivity, remember to recharge the
batteries periodically (at least once every two
months) so that they are kept at the maximum
charge level.
-
Disconnect the batteries from the machine.
-
Make certain that the debris bin is completely
empty and perfectly clean.
OPERATIONS
OPERATIONS
ON TAKING
EVERY 30 HOURS
DELIVERY
X
X
OR EVERY TWO
WEEKS
X
! ATTENTION: remember to check the batteries — if
they are not recharged periodically as described
above, they could become damaged beyond repair.
The manufacturer is not liable for any malfunctions
resulting from neglect, improper and/or incorrect use.
! ATTENTION: when the batteries discharge to the
minimum level, make certain they are not left in this
condition for any length of time, as this can reduce
their working life. Check the battery charge level at
least once a week
EN
OPERATIONS
OPERATIONS
EVERY 50 HOURS
EVERY 100 HOURS
X (*)
X (*)
X
X
X
OPERATIONS
EVERY 400 HOURS
X (*)
X
27