Battery: removal
! ATTENTION: the operation of removing the batteries
must be carried out by a skilled technician.
!
following precautions:
Contact with the skin can cause irritation; wash
with soap and water.
Inhalation of vapours can cause irritation to the
airways; stay out in the open air and consult a
doctor.
Contact with eyes can cause irritation, wash
eyes immediately and thoroughly with water for
at least 15 minutes; consult a doctor.
! DANGER: When removing the batteries, the
skilled technician must wear the Personal
Protective Equipment (gloves, eyewear,
overalls, etc.) needed to limit the risk of
accidents; remove the ignition key from the
control panel before proceeding with the
removal operation, keep away from naked
do not cause sparks and do not smoke.
! ATTENTION: before carrying out the operations
apply the parking brake.
-
Disconnect the battery cables and bridge terminals
from the battery poles.
-
to the base of the machine.
-
Lift the batteries from the compartment using
suitable handling equipment.
REPLACING THE CENTRE BRUSH
! ATTENTION: before carrying out the operations
apply the parking brake.
This machine features a system for automatically adjusting
the pressure exerted and compensating for the central
brush wear.
The need to replace the centre brush is indicated by the
WORN BRUSHES code on the display.
To replace the centre brush, proceed as follows:
-
Unscrew the knobs and open the door on the left
of the machine.
-
Unscrew and remove the three knobs securing
the brush compartment cover.
-
Remove the cover of the brush compartment.
-
Take out the worn brush.
EN
25