ENGLISH
Slave Mode
Used to make the slave unit work in opposite to the master or to work in complete sync.
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
(normal) or
Once the mode is selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Sound Mode
The unit works to rhythm of the beat when used in standalone or master/slave mode
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
or
Once the mode has been selected, press the ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Blackout Mode
Blackout mode: when no DMX-signal is detected, the unit goes in blackout and waits for the DMX-
signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone
mode.
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
(blackout on) or
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Pan Inversion
Normal: Panning movement is not inversed.
Pan inversion: Panning movement is inversed
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
(normal) or
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Tilt Inversion
Normal: Tilt movement is not inversed.
Tilt inversion: tilt movement is inversed
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select
(normal) or
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
JB SYSTEMS
®
OPERATION MANUAL
(2 light show) mode.
mode.
(blackout off) mode.
(pan inversion) mode.
(tilt inversion) mode.
5/63
ENGLISH
Display on: display is always on.
Display off: display is off when not used.
Press the MENU button until the display shows
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button until
Press the ENTER button to toggle between
After about 8 seconds your choice is automatically saved.
Used to help you adjusting the focus of the light beam and gobos.
Press the MENU button until
Press the ENTER button so the unit goes to the "tilt 90°" position.
Press the ENTER button so the unit goes to the "pan 0°" position.
Press the ENTER button so the unit goes to the "pan 90°" position.
Press the ENTER button so the unit goes to the "pan 180°" position.
Press the ENTER button so the unit goes to the "pan 270°" position.
In the Previous 5 steps you are able to adjust the focus with the UP/DOWN buttons on the unit (the display
shows the current focus status).
Attention: please note that you can only set an "average focus" for all 5 positions, so it is not possible to set
the focus perfectly sharp for all directions.
To go back to the functions press the MENU button.
Used to activate the internal "self-test" program which shows all possibilities of the unit.
Press the MENU button until
Press the ENTER button to start the internal self-test program.
To go back to the functions press the MENU button.
Used to show the temperature inside the unit
Press the MENU button until
Press the ENTER button and the temperature of unit will show on the display.
To go back to the functions press the MENU button again.
Used to show the number of working hours of the unit.
Press the MENU button until
Press the ENTER button to show the number of working hours in the display.
To go back to the functions press the MENU button.
Used to show the software version that is installed in the unit
Press the MENU button until
Press the ENTER button to show the software version on the display.
To go back to the functions press the MENU button.
LYNX-II
JB SYSTEMS
Led Display
.
(display always on) or
Display Inversion
is shown on the display. (normal display)
(normal display) and
Focus Adjust
is blinking on the display.
Self-Test
is blinking on the display.
Temperature inside the unit
is blinking on the display.
Fixture Hours
is blinking on the display.
Software version
is blinking on the display.
6/63
®
OPERATION MANUAL
(display off when not used).
(display inversion).
LYNX-II