Figure 35.- Calibrate function selection for Sat IF Test.
2.- MEASUREMENT OF THREE PILOTS THROUGHOUT THE NETWORK
Once PROLINK-4 has been calibrated, connect the RP-050 to the point where
it will be connected the satellite dish (signal source) and start to take level
measurements in the different distribution outlets using the PROLINK-4. On the screen
will appear the attenuation values for the three pilot frequencies measured in the outlet
plug (see the following figure).
Figure 36.- Attenuation measurements in a plug.
In order to finish of measuring, press the rotary selector [4] and select from
FUNCTIONS menu the End Test option.
Page 70