Start Up And Programming; Connection To The Grid; Display - Erreka DOLFIN DOS424E Manual Del Instalador

Accionador de correa para puertas corredera
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

START UP AND PROGRAMMING

1

CONNECTION TO THE GRID

1 Connect the operator to the power supply.
2 Press the ENTER push button: the display should
light up.
Reset (rS): after connecting the electricity power
supply and activating any of the key devices, the
gate closes to the stopper, with the stopper being
assigned the position "gate closed".
2

DISPLAY

Enter
D1:
Menus display
D2:
Parameters display
D3 - D4: Parameter display value
The display goes off following a long period
without pressing any key on the control
board. Press the ENTER key to reactivate.
CHANGE OF TURNING DIRECTION: if, when
carrying out the reset (rS), the gate opens instead of
closing, it is necessary to change the turning
direction by programming parameter C1 (see "Initial
Conditions Programming (D1= "C")" on page 60).
During programming, ensure there is no
person or object in the radius of action of the
gate and the operation mechanisms.
Indications during operation:
D1 and D2:
CL
(static)
CL
(flashing)
OP
(static)
OP
(flashing)
PC
(flashing)
PO
(static)
PO
(flashing)
XX
(countdown)
Esc
StOP
PA
(static)
rS
(static)
D3 and D4:
C4
C5
E1
F1
bA
Ftço
Indications during programming
D1 (Menus): Shows the selected menu. The following
menus are available:
C
Prior Conditions menu
P
Programming menu
F
Main Functions menu
A
Advanced Functions menu
ç
Operation Counter
D2 (Parameters):
Shows each parameter of the selected D1 menu.
D3 - D4 (Parameter Values):
Shows the value or option of the selected D2
parameter.
Gate closed
Gate closing
Gate open
Gate opening
Pedestrian gate closing
Pedestrian gate open
Pedestrian gate opening
Gate on standby
Operator unlocked
Pause (operation not complete)
Gate searching for close position
Opening safety device activated
Closing safety device activated
Encoder motor shutdown
Thrust limit exceeded
Battery working
Photocells defective (pre-testing)
DOLFIN operator for sliding gates
English
59
Tabla de contenido
loading

Este manual también es adecuado para:

Dolfin dos424em

Tabla de contenido