DESCRIPTION OF THE PRODUCT
4
FUNCTIONING MODES
Automatic mode (F101)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Collective opening: the control board does not
obey
the
key
(configurable in the advanced options menu, see
"Advanced Functions Programming (D1= "A")" on
page 62).
Step-by-step mode (F102)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening: if the key device is operated
during opening, the gate halts (programmable in
the advanced options menu, see "Advanced
Functions Programming (D1= "A")" on page 62).
The display shows pause situation
The gate closes when the key device is activated again.
5
OBSTACLE DETECTION FUNCTIONING
The gate can detect an obstacle in two ways:
A- Detection by photocell or strip
Opening safety device (SG.A)
During opening: if, during opening, the opening
safety device (SG.A) is activated, the gate inverts
operation direction and slightly closes. The gate
remains on standby until a key command is received
and the display shows PAC4.
During closing: if, during closing, the opening safety
device (SG.A) is activated, the gate continues to close.
B- Direct detection (built-in safety)
During opening
If, during opening, the gate collides with an obstacle, it
inverts operation direction and slightly closes. The gate
remains on standby until a key command is received
and the display shows PAF1 or PAE1. The gate closes
when the key device is used.
50
Installation Manual
commands
during
opening
PA
.
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• If the key device or the photocells are activated
during standby, standby time restarts (configurable
in the advanced options menu, see "Advanced
Functions Programming (D1= "A")" on page 62.
Closing: the closing operation starts automatically
once standby time is finished.
If, during closing, the key device is activated, the
gate inverts operation direction and opens
completely.
Standby:the gate remains open indefinitely until the
key device is operated.
Closing: the closing process starts up by using the key
device.
If, during closing, the key device is activated, the
operator inverts the movement and the gate opens.
Closing safety device (SG.C)
During opening: if, during opening, the closing safety
device (SG.C) is activated, the gate continues to open.
During closing: if the closing safety device (SG.C) is
activated during closing, the shutter gate inverts
operation direction and opens completely. The display
shows OPC5.
During closing
If, during closing, the gate collides with an obstacle, it
inverts operation direction and opens completely. The
display shows OPF1 or OPE1.