8.3 Deactivate setting aid
0
1: close zone
2: enable zone
9 Operation
9.1 Switching state of the outputs
9.1.1 The safe state
The safe state is when at least one of the outputs A1 or A2 (OSSDs) is switched
off (zero-current state: logic "0")�
If one of the outputs A1 or A2 is switched off, the subsequent safety-related logic
unit must bring the complete system into the state defined as safe�
9.1.2 The switched state
If the damping element is in the enable zone and if there is no sensor error, both
outputs A1 and A2 (OSSDs) are enabled (logic "1")�
9.1.3 Output characteristics
The output characteristics are compatible with the input characteristics to
EN 61131-2 type 1 or 2:
10
If the sensor is undamped for more
than 2 s (> 30 mm), the setting aid
is switched off and the yellow LED
goes out�
This can also be achieved by power
off�
30
mm
< 2 s
Signal
Power
> 2 s
Signal