Concrete and Anchoring:
Anchor:
Min
Concrete
Thickness
Hilti Kwik Bolt I
4-1/4"
(3/4" x 5-1/2")
(108mm)
(1300-1600 Series
Lifts)
Hilti Kwik Bolt III
4-1/4"
(3/4" x 5-1/2")
(108mm)
(500-1200 Series
Lifts)
"Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011, and the lift owner is responsible for all charges
related to any additional anchoring requirements as specified by local codes. Contact customer service for further information at: 800.640.5438
Drill holes using 3/4" carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
16-20K 2-Post Lift Anchor Installation Reference Guide
Min Edge
Min Anchor
Installation
Distance
Embedment
Anchor Torque
6-1/4"
3-1/4"
(159mm)
(83mm)
3-3/8"
3-1/4"
(86mm)
(83mm)
*The supplied concrete fasteners meet the criteria of the American National Standard
Drill (14) 3/4" dia. holes (7 per side) in concrete floor using
holes in column base plate as a guide. See diagrams for
hole depth, hole spacing, and edge distance requirements.
CAUTION
unstable surfaces. Columns are supported only by
anchors in floor.
Run nut down just below
impact section of bolt. Drive
anchor into hole until nut and
washer contact base.
Min Concrete PSI
Strength - For All
(ft-lbs)
Standards
110
3000
(149Nm)
(20684 kPa)
110
3000
(149Nm)
(20684 kPa)
5
DO NOT install on asphalt or other similar
Manually Hand Tighten
nut with Torque wrench
to 110 ft.-lbs
Concrete pad
Maintenance
Size If Concrete
Torque Values**
Does Not Meet
(ft-lbs)
Requirements
6'x6'x6"
65
(1829 x 1829 x
(88Nm)
152mm)
6'x6'x6"
65
(1829 x 1829 x
(88Nm)
152mm)
.
SEISMIC
Varies by
location
consult with
your structural
engineer and
manufacturer's
representative.