27. DC Control Cabinet Top Bracket:
A) Secure top of DC control cabinet by mounting bracket
to the top of the column as shown in fig. 33.
B) Fasten the bracket to the column, to the extension, us-
ing the included hardware as shown in fig. 33.
5/16"-18NC x 1" Lg. HEX FLGD
WZLOCK HHCS
3/8"-16NC x 9/16" Lg. HEX FLGD
WZLOCK HHCS
Fig. 33
CABINET UPPER
MOUNTING BRACKET
5/16"-18NC HEX FLGD
WZLOCK NUT
RE-ATTACH LOWER
COVER WITH SAME
1/4"-20NC BUTTON HEAD
CAP SCREW AND
FLANGED LOCKNUT
23
C) Mount the bracket to the side of the cabinet using the
included hardware as shown in fig. 33.
D) The DC control cabinet should rest against the side of
the column.
E) Fasten the included 5/16"-18NC x 1-1/2" full thread bolt
and (2) 5/16"-18NC hex nuts to the splash shield as
shown in figures 34 & 35.
Do not overtighten the bolt and push the
ATTENTION
enclosure outward.