4.2.1
Variants
Model
Code
3475030 - 3475032
RL 70
3475031 - 3475033
3475230 - 3475232
RL 100
3475231 - 3475233
3475430 - 3475432
RL 130
3475431 - 3475433
4.2.2
Accessories (optional):
•
RADIO DISTURBANCEPROTECTION KIT
If the burner is installed in places particularly subject to
radio disturbance (emission of signals exceeding 10 V/m)
owing to the presence of an INVERTER, or in applications
where the length of the thermostat connections exceeds 20
metres, a protection kit is available as an interface between
the control box and the burner.
BURNER
Code
•
DEGASSING UNIT
It may occur that a certain amount of air is contained in the light
oil sucked up by the pump. This air may originate from the light
oil itself as a consequence of depressurization or air leaking past
imperfect seals.
In double-pipe systems, the air returns to the tank from the return
pipe; in single-pipe systems, the air remains in circulation causing
pressure variations in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the
burner in single-pipe installations.
Degassing units are provided in two versions:
CODE 3010054 without filter
CODE 3010055 with filter
•
Burner delivery
•
Light oil pressure
•
Ambient temperature
•
Ambient temperature
•
Light oil temperature
•
Light oil temperature
•
Connectors
For burner deliveries higher than 80 kg/h, install two parallel de-
gassing units
Technical description of the burner
Power supply
Length of
electrical
blast tube mm
Three-phase
250
Three-phase
385
Three-phase
250
Three-phase
385
Three-phase
250
Three-phase
385
RL 70 - RL 100 - RL 130
3010386
: max. 80 kg/h
: max. 0.7 bar
: max. 50 °C (without filter)
: max. 40 °C (with filter)
: max. 50 °C (without filter)
: max. 40 °C (with filter)
: 1/4 inch
7
GB
6069