Dometic RH 548 Manual De Instrucciones página 8

Versiónes de unidad libre y versiónes de unidad empotrada
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
GB
automatically into the circulating air and the vessel will
not need emptying.
To switch off the unit, disconnect the refrigerator from
the electricity supply and leave the cabinet door open.
After defrosting the cabinet interior should be wiped
out with a clean, damp cloth.
7.1. Automatic defrost function
The first defrosting phase commences 39 hours after
the start and lasts for two hours.
After this, the device operates for 22 hours at a time,
followed by a defrosting period of 2 hours.
7.2. Interior light
Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door is
opened.
Two sensors (B) control whether the door is open or
not and the LEDs and the door control as well will
work accordingly.
8. Reversing the door hang
Reversing is suggested to perform in the following
way, in order to avoid breaking of the hinge bolt:
Disconnect the mains
Lay the appliance down carefully on its back
Remove the four screws (1) and take out the two
fixing feet (2)
Remove the four screws (3) the upper hing (4) and
the cover cap (5)
10. Customer service
Before you call a service engineer, carry out the
following simple tests:
Problem
The appliance does not cool sufficiently
The appliance does not cool at all.
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serial-number are
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
8
(fig. 6.)
(Fig. 7,)
Too much food to be cooled was put in.
Door is not shut properly.
Internal air circulation is restricted.
CUC system stopped the operation.
Plug is not connected to the mains socket properly
There is no voltage in the mains socket.
Remove the door (6), together with the upper
hinge (4), from the housing
Insert the upper hinge (attached the miniBar)
and the covering plate in the slot on the opposite
side and secure with four screws (3).
Insert the door on the upper hinge and place it.
Mount the fixing feet (2) with hinge bolts (7)
placed into the opposite side of the feet
Check that the door closes easily and is sealed
properly.
9. Replacing the decorative
door panel
(only free-standing model)
Removing and mounting of the door is similar to
that of described in the previous, 8 chapter. (Only
the foot on the hinge-side has to be removed!)
Remove screws (4) and pull off the frame edge (5).
Slide the decorative panel (6) out of the door frame
and insert the new panel (7), so that the upper edge
of the panel runs exactly parallel to the upper edge of
the frame. A new panel can be inserted more easily
into the upper edge of the frame when the two
corners are cut off by approx. 5 x 5 mm (8). Put the
frame edge (5) back in place and secure with screws.
Place the door on the lower hinge (9), slot the
upper hinge into the opening, press together with
the door against the housing and secure with the
two screws (11).
Possible cause
11. Putting into operation
Technical data:
Model
Type
Gross volume
Mains operation
Input
Energy consumption *
Climate class
Refrigerant
* The energy consumption is measured at 12°C at 25°C environment
temperature (cellar).
(Fig. 8.)
Solution
Put in less food to be be cooled.
Check if the door is shut.
Provide inside cool air circulation.
See operating instruction 5.3.
Check if the connection is proper.
Check if there is voltage.
RH 548
MB20-60
40 litres
220 - 240V (AC
65W
0,750 kWh/24h
N
159g H 2 O+86g NH 3
loading

Este manual también es adecuado para:

Mb20-60