BFT DEIMOS BT Instrucciones De Uso Y De Instalacion página 20

Servomotor de baja tension para cancelas correderas de cremallera
Ocultar thumbs Ver también para DEIMOS BT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
ENGLISH
SWO =
Opening limit switch input activation
SWC =
Closing limit switch input activation
TH
=
Activation of software thermal protection
In the case where an obstacle is found, the NETTUNO S panel stops the
door and activates a reverse manoeuvre; at the same time the display shows
the "AMP" message.
Monitoring:
During the opening and closing phases, the display shows four digits sepa-
rated by a dot, for example 35. 4 0. The digits are constantly updated during
the manoeuvre, and represent the maximum torque reached by motor (35)
and the torque value previously set (40).
These values allow the torque setting to be corrected.
If the maximum torque value reached during the manoeuvre gets sensibly
close to the value set in the parameter menu, malfunctions may occur in the
future following wear or slight door deformation.
It is therefore advisable to check the maximum torque reached during some
of the manoeuvres carried out in the course of installation, and if necessary
set a value about 15-20 percent points higher in the parameter menu.
15.8) AUTOSET MENU (autoset)
Allows you to automatically set the Motor torque.
WARNING! The autosetting operation is carried out from closing end-of-
stroke devices. If Autoset is commanded in a different position an error
message indicating "nsvc" will be displayed and the required manoeuvre
will not take place.
WARNING!! The autoset operation is only to be carried out after checking the
exact leaf (opening/closing) movement, and correct limit-switch activation.
Set the adequate slow-down speed: by pressing OK the message ".... .... ...."
is displayed and the control unit commands an opening manoeuvre without
slow-down, followed by a closing manoeuvre without slow-down during which
the duration of the stroke is memorised. Then, the control unit commands a
second opening manoeuvre with slow-down followed by a second closing
manoeuvre with slow-down during which the minimum torque value neces-
sary for the movement of the leaf is automatically set.
During this phase, it is important to avoid obscuring the photocells, as well as
using the START, STOP, PED, CLOS or OPEN commands and the display.
After completion, if the Autoset was successful, an "OK" message will be
displayed on the control unit which will then return to the Autoset menu after
pressing the "OK" key.
If, on the other hand, the control unit displays the "KO" message, it means
that the autoset procedure has not been successfully completed; it is thus
necessary to check the wear condition of the gate and the regular movement
of the leaves before proceeding to a new autoset operation.
WARNING! During the autoset phase, the obstacle detection function is
not active, therefore the installer must control the automation movement
and prevent persons and things from approaching or standing within the
automation working range.
In the case where buffer batteries are used, autosetting must be carried out
with the control panel supplied by mains power voltage.
WARNING: the torque values determined by autosetting refer
to the slow-down speed value existing when autosetting was
performed. When modifying the slow-down speed, a new autosetting
must be performed.
WARNING: Check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
16) STATISTICS
Having connected the
universal palmtop programmer
the CONTROL UNIT / STATISTICS menu and scroll the screenful showing
the statistical parameters:
-
Board microprocessor software version.
-
Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
-
Number of cycles carried out from the latest maintenance operation.
It is automatically set to zero after each self-diagnosis or parameter writing.
-
Date of latest maintenance operation. To be updated manually from the
appropriate menu "Update maintenance date".
-
Installation description. 16 characters can be entered for installation
identification.
17) MANUAL RELEASE
The manual or emergency release is to be activated when you have to open
the gate by hand, and in any event of failed or incorrect operation of the
automation system. To carry out the emergency manoeuvre, you have to:
Insert the release knob in its appropriate seat (fig.19) and rotate it clockwise
along its entire travel. This way you set the pinion idling, thus allowing to
gate to be opened by hand.
Warning: Do not push the gate leaf hard, but help it along its
entire stroke.
To reset motorised control, rotate the knob anticlockwise along its entire
travel, remove the knob and leave it in a safe place which is known to all
the persons concerned.
20 -
DEIMOS BT - NETTUNO S-MA - Ver. 04
INSTALLATION MANUAL
In the case where a release knob with personalised key is fitted (fig.18),
proceed as follows:
Insert the personalised key in the lock, and rotate the key anticlockwise.
Grip the release knob and rotate it clockwise (fig.18) until it stops.
Push the gate leaf by hand and help it along its entire travel.
The key cannot be removed from its lock until the knob is returned to its
initial position (motorised activation).
To reset motorised control, rotate the knob anticlockwise along it entire
travel and remove the key.
18) BATTERY CONNECTION DIAGRAM (Fig.19)
19) AUTOMATION CHECK
Before allowing the automation to be used normally, carry out the following
procedure very carefully:
20) AUTOMATION OPERATION
Since the automation can be remote-controlled by means of a remote control
device or a start button, and so out of sight, the good working order of all the
safety devices should be checked regularly. In the event of any anomalous
functioning of the safety devices, consult a specialised technician immediately.
Keep children at a safe distance from the automation operation area.
21) CONTROL
The automation is used for the power-operated opening and closing of the
gate. The control can be of a number of types (manual, remote-controlled,
magnetic badge access control, etc.) depending on requirements and the
characteristics of the installation. See the specific instructions for the vari-
ous control systems. Users of the automation must be instructed about its
control and operation.
22) MAINTENANCE
Disconnect the power supply when carrying out any maintenance operations.
23) SCRAPPING
WARNING! This operation should only be carried out by qualified personnel.
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out by
type (electrical components, copper, aluminium, plastic etc.).
24) DISMANTLING
WARNING! This operation should only be carried out by qualified personnel.
When the automation system is disassembled to be reassembled on another
site, proceed as follows:
to the control unit, enter
WARNING!
Correct operation is only ensured when the data contained in the
present manual are observed. The company is not to be held respon-
sible for any damage resulting from failure to observe the installation
standards and the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
Check the correct functioning of all safety devices (limit microswitches,
photocells, sensitive edges etc.).
Check that the thrust (anti-squash) force of the leaf is within the limits
set by current regulations.
Check the manual opening command.
Check the opening and closing operations with the control devices in use.
Check the standard and customised electronic functioning logic.
Clean the lenses of the photocells every so often.
Have a qualified person (installer) check correct motor torque setting.
In the event of any anomalous functioning which cannot be resolved,
disconnect the power supply and contact a specialised technician (in-
staller). Whilst the automation is out of order, activate the manual release
to allow manual opening and closing.
Disconnect the power supply and the entire external electrical installation.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
Tabla de contenido