Metabo SXE 400 Manual De Instrucciones Original página 11

Ocultar thumbs Ver también para SXE 400:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
6. Initial Operation
Before plugging in, check that the rated mains
voltage and mains frequency, as stated on the
type plate match your power supply.
Always install an RCD with a maximum trip
current of 30 mA upstream.
6.1
Installation of sanding disc
Simple attachment and removal thanks to the
velcro-type fastening.
Simply press on the sanding sheet so that the holes
in the sanding sheet (1) are aligned with the sanding
plate (2).
7. Use
7.1
Dust extraction
To optimise the dust extraction performance, fit the
sanding disc (1) so that the holes on the sanding
disc are aligned to the sanding plate (2).
Connect a suitable extraction device. Use a suction
hose with a 35 mm connector diameter.
7.2
Setting the oscillating frequency
The oscillating frequency can also be set during
operation by turning the adjustment wheel (6).
The best way to determine the ideal setting is
through a practical trial.
7.3
Switching On and Off
Switching on:
Move switch (5) to "I" position.
Switching off:
Move switch (5) to "O" position.
8. Cleaning, Maintenance
Empty clogged dust channel (9) (see page 2
fig. A)
- Loosen the screw with hexagon spanner (7).
- Remove dust channel (9) and empty.
- Insert dust channel (9).
- Insert screw with hexagon spanner and tighten.
Clean the machine regularly. This includes
vacuum cleaning the ventilation louvres on the
motor.
Replace worn sanding plate (2) (see page 2 fig.
B)
- Remove fixing screw (on the underside of the
sanding plate (2)).
- Remove sanding plate (2).
- Put new sanding plate (2) in place (when putting in
position, turn sanding plate (2) until it engages on
the flattened bits of the carrier disc).
- Refit fixing screw (on the bottom side of the
sanding plate (2)) and tighten.
Readjust braking ring (4) (see page 3 fig. C)
When the braking force decreases, the braking ring
(4) can be readjusted. Loosen the screw and push
the braking ring (4) forward to the sanding plate (2)
until light contact is established. Tighten the screw
again.
Replace braking ring (see page 3 fig. D)
To change the worn braking ring (4) remove the
sanding plate (2), remove the tensioning band, (3)
remove the old braking ring (4) and put on the new
one until the stop. Refit the tightening band (3) and
sanding plate (2).
Note: If abrasive material (e.g. gypsum, etc.) is
being sanded, the braking ring inevitably wears
faster.
9. Accessories
Use only genuine Metabo accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating
instructions.
For the complete range of accessories, see
www.metabo.com or the main catalogue.
10. Repairs
Repairs to electrical tools must ONLY be
carried out by qualified electricians!
A defective mains cable must only be replaced with
a special, original mains cable from Metabo, which
is available only from the Metabo service.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.
11. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Packaging materials must be disposed of according
to their labelling in accordance with municipal
guidelines. Further information can be found at
www.metabo.com in the "Service" section.
Only for EU countries: never dispose of
power tools in your household waste! Used
power tools must be collected separately and
handed in for environmentally compatible recycling
in accordance with European Directive 2012/19/EU
on waste electrical and electronic equipment and its
implementation in national legal systems.
12. Technical Specifications
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
D
= Diameter of sanding plate
P
= Rated input power
1
P
= Power output
2
n
= Idle speed
0
n
= Speed at rated load
1
S
= Oscillating circuit diameter
ENGLISH en