Atornille ambas piezas juntas.
Tenga precaución en no apretar demasiado la conexión. De lo contrario, el eslabón giratorio del
medidor podría ser dañado.
DATOS TÉCNICOS
Descripción
Caudal
Máxima presión en function:
Temperatura de trabajo:
Aproximaciones (no probadas)
Aproximaciones
Viscosidad de aplicación
5-dígitos LCD display
Boca de salida/entrada
EN
MANUAL OF INSTRUCTIONS
GENERAL
The digital meter gun with rigid or flexible tube. The manual or Auto-manual tip with the appropriate
connection to establish a controlled flow through the meter.
METER
5-digit liquid crystal display.
4 units: L, GAL, PT and QT.
Accurate to the second decimal place.
Low battery indicator.
4 buttons: "Total", "Reset", "1" and "2" (back of the meter).
ATTENTION: Do not apply the meter as a measuring tool for commercial
trading.
DETAILS OF OPERATION
1. Before putting into operation:
Check the technical data of the installation match with those of the lube meter. For example
connections, pressure, flow range and medium. Use the formula:Proper correction factor= (ac-
tual Value/ displayed value) x current correction factorto decide the right connection factor, then
set the proper correction factor (refer to 3. Button usage part).
Once the meter has been installed, please make sure that no air pressure shocks or particles
can damage the meter.
Please check all connections to leakage.
2. Change the battery
Battery type: Lithium CR1 23A, 3V/1 400 mAh
Last for 8 years of operation, corresponds to approx. 500,000 litres (1 32.000 US GAL)
Change the battery like below when the battery signal is flashing on the display:
Remove the protector cover, unscrewing the screw.
Change the battery and screw the lid on again.
3. Button usage
Total → Totalize the volume.
Reset → 0.00
"1" → Into Correction Factor or measurement
unit change mode.
"2" → Activate the meter again incase it is dead.
América
0-9.2gpm
1500 psi/100 bar
14°F-+122°F
±0.5%
±0.3%
8-5000mPas
Quarts, Pints, Gallons
½" NPT
· 3 ·
Europa
0-35L/m
1500 psi/100 bar
-10°C-+50°C
±0.5%
±0.3%
8-5000mPas
Liters
½" BSP