11) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench "B". Now unscrew injector "A" (see
fig. 14) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
BURNERS
DESCRIPTION
1
RAPID
2
SEMIRAPID
3
AUXILIARY
34
CONVERSIONS
BURNER ARRANGEMENT
GAS
NORMAL
PRESSURE
mbar
30
BUTANE
NATUREL
20
30
BUTANE
20
NATUREL
30
BUTANE
20
NATUREL
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 10. The technician must reset any
seals on the regulating or pre-regulating
devices. The envelope with the injectors and
the labels can be included in the kit, or at
disposal to the authorized customer Service
Centre. For the sake of convenience, the nominal
rate table also lists the heat inputs of the burners,
the diameter of the injectors and the working
pressures of the various types of gas.
TABLE
NORMAL
INJECTOR
RATE
DIAMETER
g/h
l/h
1/100
mm
83
218
11 S
286
65
127
97 Z
167
73
50
95
72 X
FIG 14
NOMINAL
BY PASS
HEAT INPUT
(W)
Min.
Max.
1/100
mm
2800
45
2800
45
35
1750
35
1750
32
4 0
1000
32
1000