StetSom SMC Manual De Usuario página 22

Idiomas disponibles

Idiomas disponibles

Scan: Performs frequency scan with the option
to select start and end frequency, gain control,
and scan speed. During the scan, the control
options are disabled, returning after the scan
is complete.
The feature can be accessed by the main menu
at "Audio Generator".
SCAN
Beginning: 10 Hz
SCAN
End: 22000 Hz
SCAN
Gain: -45.0 dB
SCAN
Speed: medio
SCAN
OFF
When scanning is activated, a continuous cycle
starts. To end it, press one of the HOTKEYS or
move the ENCODER.
Pink Noise: It generates a signal that maintains
the same magnitude for the entire frequency
scale, generally used to calibrate audio systems
to obtain a flat response and with the proper
alignment between the channels.
The feature can be accessed by the main menu
at "Audio Generator".
[ON]
42
PINK NOISE
Gain: -45.0 dB
PINK NOISE
OFF
Each press of the ENCODER switches between
editing the gain parameter and ON/OFF. With
pink noise on, it is still possible to change
the noise gain in real-time, as well as other
processor audio parameters.
Voltmeter
This option allows you to check the battery
voltage in real-time, monitor charging, and
visualize oscillations, in addition to minimum
and maximum voltage values.
The feature can be accessed by the main menu,
at "Voltmeter".
Voltmeter
Current: 12.69 V
Voltmeter
Max: 13.77 V
Each press on the ENCODER switches between
Current, Max, and Min load voltages. The
registers are lost when the processor is turned
[ON]
off.
43
loading