GB
MT
Trouble shooting
Problem
Device does not
start
Device works
with interrup-
tions
Weak or no
blowing power
36
Possible cause
Battery discharged (2)
Battery (2) not inserted
On/off switch (11)/control panel
is broken
Defective motor
Blower pipe (4) not properly at-
tached
Internal loose contact
On/off switch (11)/control panel
is broken
Low battery power
Corrective action
Charge the battery
(see "Charging the battery")
Insert the battery (see "Inserting/
removing the battery")
Repair by Service Centre
See the section on "Initial use"
Repair by Customer Care
Charge battery (2)
(see "Charging the battery")