For the machine to maintain the specified
vibration values, always check the following:
Too large a clearance between the insertion tool s
shank and the chisel bushing will generate
increased vibrations. To avoid getting exposed to
excessive vibrations, check the chisel bushing for
wear every day.
If the machine has a vibration-absorbing
handle/handles, check that it moves freely (up
and down) and does not jam.
Change damaged parts immediately.
Replace worn components in good time.
Make sure that all the attached and related
equipment, such as hoses, water separators and
oilers are properly maintained.
Periodic maintenance
After each operating period of approximately 150
impact hours or twice a year the machine must be
dismantled and all parts be cleaned and checked.
This work must be performed by authorised staff,
trained for this task.
9800 0832 90b | Original instructions
www.CrowderSupply.com • Toll Free: 888-883-5144
Safety and operating instructions
Assembly instructions
Torque: 50-60 lbf.ft (68-81 Nm), use Loctite®
A.
243™ (Loctite is a registered trademark of
Henkel Corporation. 243 is a trademark of
Henkel Corporation.)
B.
Torque: 400 lbf.ft (542 Nm).
C.
Torque: 52 lbf.ft (70 Nm).
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
Check that the insertion tool being used has the
correct shank dimension.
Check that the pneumatic machine is getting the
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or
uneven performance.
Check that the compressed air system supplies
the machine with sufficient air pressure to give
full power.
Check that the dimension and length of the air
hose are according to the recommendations. See
"Installation".
17
loading

Este manual también es adecuado para:

Cp 0122 sCp 0125 sCp 0122 svr