Failure to comply with this instruction will lead to anormal oxidation of the metallic parts which could
result in complete breakdown of the device.
The assembly of the devices (according to the model) must be performed strictly in compliance with the
following layout diagram.
2

CONTROLLER BOX

1
Choose a location that is easily accessible, close to the pump timer, far apart 2 meters maximum from
the chlorinator cell. Install the controller box vertically, far enough away from the pool to comply with
the regulatory distance in force in your country. Do not cover.
Beforehand, turn off the differential circuit breaker. Controller must be permanently connected to the
pump timer by enslaving to the pump timer. Do not use an extension cord. Do not plug the device
into an electric power outlet. Ensure that the controller box
pump stops.
2
Any contact between the controller box and the water can pull a risk of electrocution

CHLORINATOR CELL

2
Install the cell horizontally and after, any other device of treatment, cleaning or heating (just before
the water jet).
The cell mounting in by pass is recommended if we want facilitate maintenance operatings.
On line cell
Use if necessary the supplied reducers.
With sandpaper, you have to abrade pipe and jointing parts.
Apply silicon grease on cell seals
good PVC glue) the group on the pipe.
MINISALT – PAPI004086MULTI – FR/EN/DE/IT/ESP/PT – Rev.05.16
1
. Then apply the collars and hand tightens the nuts
2
T assembly of the cell
well switches off when the filtration
1
1
. Stick (with
3
4