Powermate POWER Serie Manual Del Operador página 6

Generador electrico
Idiomas disponibles

Idiomas disponibles

A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B.
120 Volt GFCI Receptacle
Ground Fault Circuit Interrupter duplex receptacle is rated so
that a total of 20 amps may be drawn regardless of whether both
halves or just one receptacle is used. This receptacle may be used
along with other receptacles provided the generator is not overloaded
and total power drawn is kept within nameplate ratings.
Ground Fault Circuit Interrupter
(Conforms to U.L 943, Class A and NEC requirements)
This device protects you against hazardous electrical shock that
may be caused if your body becomes a path through which electricity
travels to reach ground. This could happen when you touch an
appliance or cord that is " live " through faulty mechanism, damp or
worn insulation, etc.
The GFCI receptacle cannot be reset once tripped, unless the
generator is running and power is available to it. Test regularly to
assure proper operation.
C. 120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the 120/240 volt
receptacle, provided it is the only receptacle used. Total current must
be limited to the nameplate rating. If the 120/240 volt receptacle is
used along with the 120 volt receptacle, the total load drawn must not
exceed the nameplate ratings.
D. Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
J
P
Q
I
H
English
GENERA
T
OR FEA
GENERA
T
OR FEA
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The
circuit protector may be reset by pushing the button of the protector.
E.
F.
G.
H. 389 CC OHV Engine
I.
J.
K. Oil Filler Cap
L.
M. 6.5 Gallon Metal Fuel Tank
N. Fuel Tank Cap
O. Fuel Gauge
P. Fuel Shut-Off Valve
Q. Air Filter
G N
M
S
L
6
TURES
TURES
Ground Terminal
Hour Meter
Engine On/Off Switch
Recoil Starter
Engine Choke Lever
Oil Drain Plug
F
O
K
B
R
Customer Hotline 1-800-445-1805
D
C
D
E
A
loading

Este manual también es adecuado para:

Power pmc105007