PLM+ SERIES
Input Connectors
(1) Analog Inputs – Four analog inputs are available on standard XLR-3F connectors, electronically balanced and featuring Lake Iso-Float circuitry. Impedance is
20 kohms; maximum input level is +26 dBu.
(2) AES3 Inputs – Two latching XLR-3F connectors accept four channels of AES3 digital audio. Input impedance is 110 ohms; ensure that 110 ohm digital audio
cables are used.
Output Connectors
PLM 20K44, 12K44 and 8K44 are equipped with one of the two output connector options. Both options allow for Bridge Mode operation, which is activated in the
Lake Controller software. Please refer to the Lake Controller Operation Manual for more information. The PLM 5K44 is equipped with both binding posts and speakON
connectors, and does not support Bridge Mode operation.
(3) Binding Posts – Power outputs are available on four separate pairs of fully enclosed binding posts.
(4) speakON connectors – For PLM 20K44, 12K44 and 8K44, power outputs are available simultaneously on a single 8 pole connector and on two 4 pole
connectors. The four-pole connectors carry outputs for channels 1&2 and 3&4 respectively. For PLM 5K44, connector 1 carries output channels 1 and 2,
connect, or 2 carries channel 2, connector 3 carries channel 3 and 4, and connector 4 carries channel 4.
Ethernet and Power Connectors
(5) Primary Network Connector – The primary Neutrik RJ45 etherCON® connection provides integration into an Ethernet control network which may include
other Lake Processors and the Lake Controller software. Network connection permits full control of all functions along with real-time metering from a remote
position. This device supports the Dante audio networking protocol for multichannel, high-de nition digital audio over the same Ethernet connection.
Use the primary connector when using a star network topology, consisting of individual Cat-5e connections between the devices and an Ethernet switch. Alternatively,
this connection can be used to daisy chain directly to another Lake Processor. Daisy chain topology is not recommended for use with Dante or AES67.
For a technical reference of the Ethernet Port, please refer to the full PLM+ Series Operation Manual. Additional information is also available in the
Lake Network Con guration Guide.
Note: Additional processor con guration is required for a dual redundant network setup. See the Lake Controller Operation Manual for further details.
Note: Do not create a closed loop when con guring multiple devices in an Ethernet network; this will cause a network malfunction.
(6) Secondary Network Connector – The secondary network connector can be used to daisy-chain multiple PLM+ Series devices. Alternatively, a Dante dual-
network topology can be created by connecting all secondary network connectors to a separate Ethernet switch, ensuring full redundancy in the event of a
network component failure. Dual Redundancy needs to be enabled for this operation (can be done from Lake Controller or front panel).
(7) Mains Power Connector – AC mains input for the PLM 20K44, 12K44 and 8K44 is via a Neutrik powerCON connector, rated at 32A. Connector mates with
supplied AC mains cable. PLM 5K44 uses a standard IEC locking connector. See previous section on Operating Voltage for more information.