Error Messages
When you turn on the device, it will make a reset first. The display may show "XXEr" while there are
problems with one channel. "XX" stands for the channels equipped with a testing sensor.
When the display shows "01Er", it means there is some error in channel 1.
01Er:
(PAN movement error) This message will appear after the reset of the device if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The plate is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The cooling-fans should be cleaned monthly.
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
Do not operate this device with opened cover!
40/79
00024219.DOC, Version 1.2