OPERATING INSTRUCTION
8
Maintenance
en
9
Technical specifications
Recommended sensing range for the best performance
Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Switching frequency
Response time
Enclosure rating
Protection class
Circuit protection
Ambient temperature, operation
1)
Limit values
Reverse polarity protected U
Residual ripple max. 5 V
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
Reference voltage DC 50 V
5)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
24
O P E R A T I N G I N S T R U C T I O N | GRSE18
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
•
Clean the optical interfaces and housing
•
Check the fittings and plug connectors
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
■
Never use sharp objects for cleaning.
■
Clean the optical surfaces at regular intervals and, in the event of contamina‐
b
tion, with a lint-free lens cloth (part number 4003353) and plastic cleaner (part
number 5600006). The cleaning interval essentially depends on the ambient
conditions.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
connections
B
ss
GRSE18-xxx4x
GRSE18-xxx2x
0 ... 15 m
0 ... 15 m
0 ... 15 m
0 ... 15 m
250 mm / 10 m
250 mm / 10 m
DC 10 ... 30 V
1)
DC 10 ... 30 V
100 mA
100 mA
1,000 / s
1,000 / s
2)
< 0,5 ms
< 0,5 ms
3)
IP67
IP67
III
4)
III
4)
A, B, D
A, B, D
5)
-25 °C ... +55 °C
-25 °C ... +55 °C
8016954.1HT2/2022-11-11 | SICK
Subject to change without notice
1)
2)
3)
5)