SICK GRSE18 Instrucciones De Operación página 23

Ocultar thumbs Ver también para GRSE18:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Table Fault diagnosis
7
Disassembly and disposal
8016954.1HT2/2022-11-11 | SICK
Subject to change without notice
LED/fault pattern
Green LED does not light up
Green LED does not light up
Green LED does not light up
Green LED lights up, no output
signal when object is detected
Yellow LED flashes
Yellow LED lights up, no object
in the path of the beam
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
OPERATING INSTRUCTION
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Test input (Test) is not con‐
nected properly
Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
The beam of light of a pho‐
toelectric through-beam sen‐
sor hits the receiver of
another (neighboring) photo‐
electric through-beam sensor
O P E R A T I N G I N S T R U C T I O N | GRSE18
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
See the note on connecting
the TI
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
receiver. / Clean the optical
surfaces . / Readjust the sen‐
sitivity (potentiometer) / If the
potentiometer is set to the
max. sensing range: Reduce
the distance between the
sender and the receiver and
check / Check sensing range
and adjust if necessary,
see
"Check the application condi‐
tions", page
18.
Swap the sender and receiver
arrangement at every sec‐
ond through-beam photoelec‐
tric sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
23
en
loading