Gaggenau CM 450 712 Manual De Instalación página 17

Idiomas disponibles

Idiomas disponibles

7
Insert the cover
(X)
fastening screws
(i)
8
Replace the drip tray
and close the appliance door.
(Z)
and fix with the two black
.
Fig. 18
(Y)
and accessories drawer
Fig. 19
Fault in water flow
To ensure an adequate water flow, the filter in the
AquaStop should be cleaned regularly.
1
Turn off the tap.
2
Unscrew the water inlet hose with the AquaStop
from the tap.
3
Clean the filter with a small brush.
Important:
Do not remove the filter under any
circumstances.
4
Screw the water inlet hose with the AquaStop to the
tap.
5
Slowly turn on the tap so it is fully open.
6
Check the connections and water inlet hose for
leaks.
If the appliance is cleaned and maintained regularly, this
will avoid faults.
17
loading

Este manual también es adecuado para:

Cm470712Cmp 250 711