ELECTRICAL CONNECTION
Prior to carrying out the electrical connection, please ensure that:
-
the plant characteristics are such as to follow what is indicated on the
data plate placed at the bottom of the working area;
-
that the plant is tted with an e cient earth connection, following
the standards and law provisions in force.
The earth connection is compulsory in terms of the law. Should there be
no cable and/or plug on the equipment, use suitable absorption material
for the working temperature as well, as indicated on the data plate.
Under no circumstance must the cable reach a temperature above 50°C
of the ambient temperature.
If connecting directly to the mains power supply, t a multi-pole switch
of a suitable size for the rated capacity with a clearance distance which
completely disconnects the power line under overvoltage category III
conditions, consistently with the rules of installation (the yellow/green
earth wire must not be interrupted).
The plug or omnipolar switch must be easily reached on the installed
equipment.
The manufacturers decline any responsibility in the event of non-
compliance with what is described above and the accident prevention
norms not being respected and followed.
OVERVIEW
1. Cooktop
2. Control panel
To avoid all risk, if the power cable becomes damaged, it must only be
replaced by the manufacturer, by an authorised service centre, or by
a quali ed electrician.
THE POWER CABLE MUST ONLY BE REPLACED BY A QUALIFIED
ELECTRICIAN.
400V 3N~
400V 2N~
230V~
Fig. 3 Considering contemporaneity factor
1
2
– 8 –
H05RR--F5x1.5
2
4
3
1
5
L1 L2 L3
N
H05RR--F4x1.5
2
4
3
1
5
L1 L2
N
* H05RR--F3x2.5
2
4
3
1
5
L
N
loading