Important Notes; Application; Technical Specifications - Franke AQCT0031 Instrucciones De Montaje Y Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
4.

Important Notes

• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• Battery compartment including battery or power supply and extension cables must
be ordered separately (see Accessories,
• All work must be carried out in a de-energised state.
• All rights reserved to make technical alterations.
5.

Application

AQUACONTACT – Shower panel made of mineral composite MIRANIT-S, for
surface installation, with electronic time-control, battery-powered or mains operation.
For connecting to pre-mixed warm water or cold water.
Flow duration 30 seconds.
With integrated hygiene flushing (24h after the last use, for 10s). Functions are
activated with a reflection code on the sensor: Activation/deactivation of hygiene
flushing and cleaning shut-off (3 min).
Additional functions via optional remote control:
– Adjustable flow duration and time intervals
– Switchable from time-control to body reflection, maximum flow duration 300
seconds
– Program controlled thermal disinfection with safety switch-off
6.

Technical Specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Supply voltage:
Power consumption:
Type of protection:
Chapter
1.0 bar
1–5 bar
10 bar
0.20 l/s
6 V DC
1.5 W
IP 67
- 5 -
25).
Tabla de contenido
loading

Este manual también es adecuado para:

Aqct0032

Tabla de contenido