2.
Abbreviations and terminology
TWW
TW
SW
DN
FAR Order No.
EA No.
Conversion
All length specifications in the graphics are in mm.
3.
Important notes
• Installation, commissioning and maintenance are to be performed only by a qualified
technician according to the instructions provided.
• Legal requirements and the technical connection regulations of the local water supply
companies must be complied with.
• Before assembling and installing the equipment, flush the supply pipes in accordance
with DIN 1988!
• Only operate this valve in conjunction with the correct grit filters.
• If the temperature of the hot water supply is above 45 °C, the temperature limiter
must be set to prevent scalding (see
• Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for cleaning.
• All rights reserved to make technical alterations.
4.
Technical specifications
Minimum flow pressure
Calculation flow rate
Volume flow 2152 00 23
Volume flow 2154 00 23
Flow time at 38 °C
4
Warm drinking-water
Drinking-water
Width A/F
Nominal diameter in mm
Franke-AQUAROTTER Order No.
European article number
1 mm = 0.03937 inches
1 inch = 25.4 mm
Chapter
11.).
1.0 bar
TW 0.07 l/s (4.2 l/min), TWW 0.07 l/s (4.2 l/min)
0.10 l/s (6 l/min) at 3 bar flow pressure
0.13 l/s (7.8 l/min) at 3 bar flow pressure
1 – 30 s adjustable