RC(S)(L)(D)10-Series
Mounting the compressor unit
A
NOTICE! Damage hazard
• Lay the suction pipe in such a way that it is not damaged (e.g. by
sharp edges or strong bends). Observe the minimum bending
radius of the suction pipe (≥R30 mm).
• Ensure that the air from the compressor unit can flow out through the
ventilation grille without obstruction. Do not block the air flow and
do not cover the ventilation grille (e.g. by a closed cabinet door).
1. Place the compressor unit in the duct with the fan side facing the ventilation
grille.
2. Install the compressor unit (1) as shown (fig. 9, page 8).
4.3
Installing the condensate drain
I
NOTE
• Condensation can form inside the refrigerator due to frequent door
opening, incorrectly stored food or food that is stored when it is too
warm.
• Condensation must be drained with a constant slope.
Install the condensate drain as follows:
➤ Run the condensation water hose from the refrigerator through an opening in the
floor which goes outside.
4.4
Connecting the power supply
A
NOTICE! Damage hazard
• The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable national regulations and
standards.
• To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if
possible. For this reason avoid additional switches, plugs or power
strips.
• Before connecting check whether the operating voltage and the bat-
tery voltage correspond (see type plate).
EN
Installing the refrigerator
17