MEDIO - GRANDE
EN
MAINTENANCE
7.3.1
CLEANING THE PLEXIGLAS COVER
• Wipe using a cloth soaked in potable water or a detergent specially meant for Plexiglas (maximum temperature 40°C).
• Do not use other types of detergents.
• Dry the cover thoroughly.
7.3.2
CLEANING THE SEALING BARS
ATTENTION!
Do not start cleaning operations with the sealing bars hot, as there is danger of burns.
• Clean the upper part of the sealing bar using a clean cloth soaked in potable water.
7.3.3

CLEANING THE VACUUM CHAMBER

1) Switch the machine off by means of the ON/OFF main switch and disconnect the plug from
the mains socket.
2) Disconnect the two sealing bar connection wires (A - Fig. 1).
3) Remove the sealing bar together with the connection wires (Fig. 2).
4) Hold the sealbag and pull it upwards (B - Fig. 3).
5) Insert the safety cap (C) in the central opening as shown in (Fig. 4).
6) Using a cloth soaked in a detergent and/or disinfectant solution, clean the bottom and
sides of the vacuum chamber (Fig. 5); after cleaning, refit the parts by repeating the above
operations in reverse order.
Fig. 2
7.3.4

DISINFECTING THE MACHINE

• Switch the machine off by means of the ON/OFF main switch and disconnect the plug from the
mains socket.
• Spray the machine's stainless steel surface with an alcohol-based disinfectant. Do not spray
on the electrical parts or in the machine's air vents.
• Leave the disinfectant to act for a few minutes.
• Wipe with a cloth soaked in potable water, then dry thoroughly with a clean cloth.
7.3.5. THE DEUMIDIFICATION CYCLE
In order achieve longer pump life and greater pump performance, we recommend carrying out a weekly pump dehumidification cycle. This is necessary
to evacuate humidity from the oil and from the actual pump.
In order to clean the suction nozzles, carry out the DEHUMIDIFICATION CYCLE program.
Activate the dehumidification cycle in the following way
1) Switch the machine ON
2) Push
by positioning on program "H2O OUT" on the display
3) Start the cycle by lowering the lid.
4) At the end of the cycle, which has duration of 20 minuts, select the destre work cycle by pressing the cursor keys
The deumidification cycle can be interrupted at any time by pressing the STOP button.
Operating and service manual / Mode d'emploi et d'entretien
Manual de uso y mantenimiento / Ed. 01 - 2011
A
B
Fig. 3
32
VACUUM PACKING MACHINE
CONDITIONNEUSE SOUS VIDE
MAQUINA DE VACÍO
A
Fig. 1
C
Fig. 4
Fig. 5
REV. 00 - Cod.: 1500386
Tabla de contenido
loading

Este manual también es adecuado para:

Grande4085040851

Tabla de contenido