Fein WSG 7-115 PT Instrucciones De Uso página 11

Ocultar thumbs Ver también para WSG 7-115 PT:
Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000277-001.book Page 11 Thursday, April 20, 2017 10:40 AM
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Intended use of the power tool:
Hand-guided angle grinder for dry grinding,
sanding with sanding discs, working with wire
brushes and cutting of metal and stone in
weather-protected environments with the
application tools and accessories recom-
mended by FEIN.
Operation of the power tool off power
generators.
This power tool is also suitable for use
with AC generators with sufficient
power output that correspond to the Stan-
dard ISO 8528, design type G2. This Standard
is particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
Recommended dimensions of extension
cables at an operating voltage of 120 V – sin-
gle-phase a. c., with only one power tool
WSG7-115 PT (**) connected:
Max. cable length, ft
Max. cable length, m
≤ 100
100
200
–200
–300
Min. conductor size
Min. conductorcross-
A.W.G.
section, mm
16
14
12
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
en
11
≤ 30
30
60
– 60
–100
2
1.5
2.5
4
loading