TIMER
OFF
DAY
SEG
Fig. 11
- Time setting: Press MODE to set the val-
ues desired: Week (1-7), minutes (0-59)
and hours (0-23). Then press the
buttons to adjust the element, whish
is set by pressing TIME or cancelled by
pressing TIME once again. The characters
flash during adjustment. If these flash
during cancellation, the setting could con-
tinue until deleted by pressing ON/OFF
(Fig. 12).
DAY
Fig. 12
- Cancellation of timer: Press the
buttons to select the day of the week, and
then press TIME to confirm ("dd" will ap-
pear on the display). The day of the week
can also be cancelled by pressing TIME
without "dd" appearing on the display.
Press ON/OFF to finalize (Fig. 13).
10
TIMER
MODE
FAN
SLEEP
TIME
ON/OFF
Outdoor ambient temperature (Fig.
14)
Pressing the SLEEP button for 5 seconds,
OUT ENV appears on the display. This al-
lows reading the outdoor temperature.
- If the outdoor temperature is over 0° C,
no value will appear in the temperature
and
area of the display, and the outdoor
temperature will appear in the ambient
temperature area.
- If the outdoor temperature is below 0° C,
they symbol "-" will appear in the tempera-
ture setting and the outdoor temperature,
in absolute value, will appear in the ambi-
ent temperature area.
MODE
FAN
SLEEP
TIME
ON/OFF
The screen will display the indoor tempera-
ture once again after 10 seconds.
AUTORESTART (Fig. 15)
By pressing the MODE button for 10 sec-
onds you can set unit status in case of power
failure. In the temperature area, select:
and
- "01" If the unit is to memorize the operat-
ing mode in case of a power failure.
- "02" If the unit is not to memorize the
operating mode in case of a power
failure.
Press ON/OFF to confirm the system se-
lected.
MODE
DAY
FAN
SLEEP
TIME
ON/OFF
Fig. 13
MODE
OUT ENV
FAN
SLEEP
TIME
ON/OFF
Fig. 14
GB
Fig. 15
Special applications (Fig. 16):
Press the FAN and SLEEP buttons simul-
taneously for 10seconds. DEBUG appears
on the display.
With the
and
keys, select the option
number and press MODE.
- Setting of ambient temperature sensor
(01).
Pressing the
and
keys, select the
status type:
01 - Ambient temperature is measured at
the unit return.
02 - Ambient temperature is measured on
the hard-wired remote control unit.
03 - Ambient temperature at the return
of the unit in COOL, DRY and FAN
modes; ambient temperature on the
hard-wired remote control unit in HEAT
and AUTO modes.
Factory-set to mode 03.
- Fan speed setting (02).
Pressing the
and
keys, select the
status type:
01 - 220V (fan speed not adjustable).
02 - 200 V.
03 - 180 V.
04 - 160 V.
05 - 140 V.
Factory-set to mode 01.
DEBUG
Fig. 16
MODE
FAN
SLEEP
TIME
ON/OFF
MODE
FAN
SLEEP
TIME
ON/OFF