Connecting The Battery Charger - Dometic TEC 29 Instrucciones De Montaje

Ocultar thumbs Ver también para TEC 29:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
TEC29, TEC29LPG
10.3
Connecting 230 V
A
NOTICE!
 Connect a relay or a switch to the vehicle's electrical system
so that the generator is not damaged when the external mains
is connected.
 Ensure that the electrical system is set up as follows:
– TN network:
The neutral conductor must be linked to the PE conductor
on the terminal via a jumper with a minimum diameter of
2.5 mm
sure that a safety switch (FI switch, 30 mA) and an in all-
pole overcurrent protection (e.g. circuit breaker, 13 A) are
installed.
– IT network:
Ensure that an insulation monitor and an in all-pole over-
current protection (e.g. circuit breaker, 13 A) are installed.
 Connect the generator so that it takes priority over the power
supply.
➤ Guide the 230 V connection cable through the cable passage in the
housing and connect it to the 230 V terminals (for TEC29: fig. e 7,
page 10, for TEC29LPG: fig. f 6, page 10).
➤ Connect the earth cable to the earth connection on (for TEC29: fig. e 6,
page 10, for TEC29LPG: fig. f 7, page 10).
10.4

Connecting the battery charger

➤ Connect the positive terminal of the battery with the 12 V connection of
the battery charger using a cable with a cross-section of 2.5 mm² (for
TEC29: fig. e 5, page 10, for TEC29LPG: fig. f 8, page 10).
➤ If the battery to be charged is not also the starter battery, connect the
negative terminal of the battery to be charged to the generator's earth
cable (fig. g 1, page 11).
EN
Connecting the electrical power to the generator
2
. To protect against automatic shutdown, make
27

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Tec 29lpg

Tabla de contenido