BMP 01- EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
7
IO-Link interface (continued)
7.3
Identification data
Index
Subindex
0×0010 (16)
0
0×0011 (17)
0
0×0012 (18)
0
0×0013 (19)
0
0×0014 (20)
0
0×0015 (21)
0
0×0016 (22)
0
0×0017 (23)
0
0×0018 (24)
0
0×0019 (25)
0
0×001A (26)
0
Tab. 7-4:
Identification data
Application Specific Tag, Function Tag and
Location Tag
The Application Specific Tag, Function Tag and
Location Tag tags offer the ability to assign any max
32-byte string to the IO-Link device. This can only be used
for application-specific identification and applied in the
parameter manager. The entire object is accessed via
subindex 0.
www.balluff.com
Parameter
Vendor Name
Vendor Text
Product Name
Max. 40 bytes
Product ID
Product Text
Serial Number
Max. 18 bytes
Hardware Revision
Firmware Revision
Application Specific Tag
Max. 32 bytes
Function Tag
Max. 32 bytes
Location Tag
Max. 32 bytes
.
Size
Access
7 bytes
Read Only
15 bytes
Read Only
Read Only
12 bytes
Read Only
27 bytes
Read Only
Read Only
2 bytes
Read Only
9 byte
Read Only
Read/Write
Read/Write
Read/Write
Data storage
X
X
X
english
19