SKF LINCOLN Centro-Matic P653S Serie Instrucciones De Uso Y Mantenimento página 27

Ocultar thumbs Ver también para LINCOLN Centro-Matic P653S Serie:
Idiomas disponibles

Idiomas disponibles

Display
Press
Complete programming
Press button. P - is displayed.
NOTE
Always carry out programming completely in
order to save new values.
• Press key (additional lubrication) to
complete programming and to save
entered parameters.
NOTE
If button additional lubrication is not
pressed within 30 seconds, changed
parameters will not be saved and previous
programming remains valid.
NOTE
After completion of programming, check
parameter settings in operating mode once
again.
Programming of pump with pressure switch
is complete.
Programming mode:
Step 7
Pump with pressure
transducer
Complete steps 1 through 6
of pump with pressure
switch
Display
Press
Display
Press
NOTE
P7 programming will only appear if pump
has internal pressure transducer.
P7: Programs setting of where
internal pressure transducer will close.
This is the maximum pressure that pump
can reach. Factory setting is
3 500 psi (240 bar).
Step 7
1400 to 4600 psi (96 to 317 bar) in
100 psi (6,9 bar) increments.
27
Press button to change value.
Reading x 100 = Transducer setting in psi
35 x 100 = 3 500 psi (240 bar).
This setting is adjustable from
loading

Este manual también es adecuado para:

Lincoln centro-matic p653s-4-x-l-f-24-2a-as06