P2: Setting minutes
Press button, so that P2 appears in
display.
When releasing button, currently set
value appears (here factory-set value: 0
minutes).
Minute is indicated by dot on the left-
hand side.
Press button.
Settings are made in one direction: 0, 1, 2,
3, 4, 5, .... 59 min
Button pressed once: increase by
1 minute
Button pressed continuously: quick
sequence. Example: 30 minutes
NOTE
If hours are set to 00, display will show
minimum pause time of 4 minutes.
Step 3
Display
Press
Display
Press
P4: Programming of output signal for both
alarm relays. Default setting on printed
circuit board for alarm contacts is switching
to battery minus.
Press button so that P4 appears in display.
When releasing button, currently set
value appears in display (here factory-set
value NO, normally open contact). On fault
condition alarm contact will close.
Press button.
External fault contact is modified by
programming it as NC normally closed
contact. On a fault condition alarm
contact will open.
Step 4