2. Installation location
B
L
F
G
Fig. 2-1
3. Installing the indoor unit
Fig. 3-1
F
D
5/8
0
31/32
1-31/32
2-15/16
3-15/16
4-19/32
4-29/32
5-19/32
7-9/16
9-17/32
11
11-1/2
C
A
K
Fig. 3-2
B
A
C
E
D
Fig. 3-3
(mm)
1170
(inch)
A
46-1/16
C K
D
E
*
J
H
–
G
A
E
3-15/16
I
J
Sleeve
Hole
(Indoors)
Wall
(Outdoors)
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and
maintenance.
Min. 100.5
Min. 52.3
Min. 3-31/32
Min. 2-1/16
Air outlet: Do not place an obstacle within 1500 mm, 59-1/16 inch of the air outlet.
Floor surface
Furnishing
When the projection dimension of a curtain rail or the like from the wall exceeds 60 mm,
I
2/23/64 inch extra distance should be taken because the fan air current may create a short
cycle.
1800 mm, 70-7/8 inch or greater from the floor surface (for high location mounting)
108 mm, 4-1/4 inch or greater with left or rear left piping.
Minimum 7 mm, 9/32 inch.
Note: (For radio frequency interface)
■
Connect a cord of the radio frequency interface to indoor controller
board before mounting the indoor unit on the wall.
■
Refer to P.9 for details on how to installation the radio frequency
interface.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PART
ACCESSORY
NUMBER
Mount board
Tapping screw 4 × 25
Felt tape
L-shaped connection pipe
Charge nut
Spacer
(inch)
3.2. Installing the wall mounting fixture
3.2.1. Setting the wall mounting fixture and piping positions
(Fig. 3-2)
B
Using the wall mounting fixture, determine the unit's installation position
2-1/8
1-1/4
31/32
and the locations of the piping holes to be drilled.
1/2
0
1/2
1-15/32
2-15/32
Warning:
3-7/16
4-1/8
5-3/32
Before drilling a hole in the wall, you must consult the building contractor.
6-9/16
8-17/32
9-1/32
Mount board
10-13/32
11-1/2
Indoor unit
12-5/32
12-1/4
Bottom left rear pipe hole (ø75-ø80 mm, 2-61/64~3-35/64 inch)
D
Bottom right rear pipe hole (ø75-ø80 mm, 2-61/64~3-35/64 inch)
Knockout hole for left rear hole (75 × 480)
Bolt hole (4-ø9 mm, 23/64 inch hole)
Center measurement hole (ø2.5 mm, 3/32 inch hole)
Tapping hole (75-ø5.1 mm, 13/64 inch hole)
Hole centre
Align the scale with the line.
Insert scale.
3.2.2. Drilling the piping hole (Fig. 3-3)
Use a core drill to make a hole of 75-80 mm, 2-61/64~3-5/32 inch diameter
in the wall in the piping direction, at the position shown in the diagram to
the left.
The hole should incline so that the outside opening is lower than the
inside opening.
Insert a sleeve (with a 75 mm, 2-61/64 inch diameter and purchased
locally) through the hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
Min. 48
Min. 250
Min. 220
Min. 1-7/8
Min. 9-27/32
Min. 8-21/32
LOCATION OF
QUANTITY
SETTING
1
7
Fix at the back of
2
the unit
1
1
Make use of
1
packaging material
(mm, inch)
3