WIKA GD-20 Manual De Instrucciones página 69

Ocultar thumbs Ver también para GD-20:
Idiomas disponibles
  • ES

Idiomas disponibles

9. Specifications
Operating conditions
Operating conditions
Vibration resistance
Shock resistance
Single shock loads
Continuous shock
Permissible temperature ranges
Ambient temperature
Storage temperature
Permissible air humidity
Ingress protection
1)
M12 x 1 plastic
M12 x 1 metal
Cable outlet plastic
Cable outlet metal
Field case
Electrical safety
Model GD-20-D
Model GD-20-A
1) The respective IP protection rating applies to electrical ouputs with plug-type design when plugged in or with cable/bling plug, respectively. The mating connector
must be suitable for the required ingress protection.
WIKA operating instructions gas density sensor, model GD-20
All manuals and user guides at all-guides.com
5 g, 15 ... 2,000 Hz, for versions with field case
20 g, 30 ... 2,000 Hz, for versions without field case
500 g (1.4 ms, 1 shock, 3 axes)
100 g (4 ms, 10,000 shocks, 3 axes)
-40 ... +80 °C [-40 ... +176 °F]
-40 ... +70 °C [-40 ... +158 °F]
≤ 95 % r. h. (non-condensing)
IP67, with mating connector
IP67, with mating connector
IP67, with cable
IP67, with cable
IP6k9k, with cable/blind plug
Reverse polarity voltage U
Reverse polarity voltage U
vs. U
DC 30 V
+
-
vs. U
DC 40 V
+
-
EN
69
loading