Any bumping or forcing can damage the fume extractor, making it noisy during
operation, therefore it is advisable to have this operation carried out by qualified
personnel.
The inspection doors have seals, so before refitting them make sure the seals are
not worn and/or damaged.
8.3.7. VARIOUS CHECKS
When the hopper is completely empty, unplug the unit's power cable and remove the residues (dust, chips, etc.)
from the hopper, before filling it.
All the sealing gaskets fitted on the pieces and components involved in maintenance (fume extractors, inspection
doors, exhaust manifolds, fire doors, etc.) must be replaced by the authorized service center at the time of the
intervention. At the end of maintenance work, check the tightness of the seals/gaskets and the correct operation
of the unit.
All maintenance operations must be carried out with the unit cold and the power
supply disconnected, using a suitable vacuum cleaner and tools for thorough
cleaning.
9.
SERVICE MESSAGE MAINTENANCE
Every 1800 operating hours or 2000 kg of pellets burned the unit alerts, via a "SERVICE" message, the request
for maintenance (not under warranty) to be planned with an authorized service center, which provides for complete
maintenance and message resetting.
Before any intervention, make sure the power supply is disconnected and that
the unit is completely cold.
Failure to comply with the above indications can compromise the safety of the
unit and may void the right to the warranty conditions.
10. REQUEST FOR INTERVENTION AND SPARE PARTS
To request assistance and/or spare parts, contact your dealer, local importer or the nearest Authorized Service
Center, providing the following details:
▪ unit model,
▪ serial number,
▪ date of purchase,
▪ list of spare parts,
▪ information on faults or malfunctions encountered.
Interventions on components must be carried out by authorized and/or qualified
personnel.
Before any intervention, make sure all electrical connections are disconnected and
that the unit is cold.
Only use original spare parts.
11. STORAGE AND DISPOSAL
11.1 SETTING ASIDE FOR PERIODS OF INACTIVITY
If the unit is not being used for long periods (and/or at the end of each season), proceed as described:
Step
Action
1
Remove all pellets from the hopper.
2
Disconnect the power supply.
3
Clean carefully and, if necessary, have damaged parts replaced by qualified personnel.
4
Protect the unit from dust with suitable covering.
5
Store in a dry and safe place protected from the weather.