Cointra CESENA 7 Instrucciones De Uso, Instalación Y Mantenimiento página 142

Idiomas disponibles

Idiomas disponibles

4.3
TECHNICAL DATA
General information
Manufacturer
Commercial brand
Model
Product description
Pellet fuel type
Other fuels
Feed type
Model ID
Overall dimensions (H x L x D)
Empty weight
Weight with packing
Pellet hopper capacity
Combustion air inlet pipe diameter
Fume outlet pipes diameter
Recommended draft at nominal output
Minimum draft permitted at reduced output
Power supply: voltage and frequency
Electrical absorption
Distance from combustible material
Maximum heatable volume with energy requirement of 30-35 W/m
Heat outputs
Heat input
Heat output
Thermal efficiency at output
Hourly consumption* at output
Fume outlet temperature at output
Fume flow rate at output
Emissions due to ambient heating
CO emission at 13% O2 at output
CnHm emission at 10% O2 mg/m
output
NOx emission at 10% O2 mg/m
output
PP dust emission at 10% O2 mg/m3
at output
Data obtained as per EN 14785 in accordance with the European Regulation for Construction Products (EU 305/2011)
* Data which may vary according to the type of pellets used
142
max
at nominal P
at reduced P
Standby
ceiling
rear
side RH - LH
floor
front
3
nominal
reduced
nominal
reduced
nominal
reduced
nominal
reduced
nominal
reduced
nominal
reduced
nominal
reduced
at
3
nominal
reduced
at
nominal
3
reduced
nominal
reduced
A73024060 - Rev 01 - 07/2023
Hermetic unit for domestic heating, without
Wood pellets diameter 6 mm with size length (3
CESENA 7
L,H,W
430 x 890 x 503
mm
m
kg
m+
kg
15 kg - 21 litri
dinlet
mm
dout
mm
Pa
pnom
0,12
mbar
Pa
ppart
0,08
mbar
E,f
Wmax
W
elmax
W
elmin
W
elSB
W
dC
mm
dR
mm
dS
mm
dB
mm
dP
mm
203 - 174
m
3
P in-nom
kW
P in-part
kW
P nom
kW
P part
kW
ɳnom
kW
88,9
ɳpart
kW
93,1
kg/h
1,42
kg/h
0,52
°C
179,6
T snom
°C
T spart
ϕf,g nom
g/s
ϕf,g part
g/s
CO nom
mg/Nm
3
CO part
mg/Nm
3
mg/Nm
OGC nom
3
mg/Nm
OGC part
3
mg/Nm
NOx nom
3
NOx part
mg/Nm
3
PM nom
mg/Nm
3
PM part
mg/Nm
3
CESENA - GARDA
FERROLI S.p.A.
COINTRA
CESENA
water, fueled by wood pellets
÷ 40) mm - UNI EN ISO 17225-2-A1
NO
Automatic
CESENA 9
CESENA 11
460 x 953 x 540
50
80
65
95
22 kg - 31 litri
50
50
80
80
12
12
0,12
8
8
0,08
230 Volt / 50 Hz
Lighting 370
52
87
33
49
2
2
800
200
200
0
800
1000
270 - 231
323 - 277
6,9
8,7
2,5
3,2
6,1
8,1
2,4
3,1
92,2
95,0
1,81
0,67
134,6
87
70,2
4,0
5,2
2,4
3,1
176
61
180
106
6
3
5
2
118
131
89
119
13
13,7
19
13,7
89
49
2
1000
10,7
3,2
9,7
3,1
90,9
95,0
2,22
0,67
159,7
70,2
6,0
3,1
100
106
4
2
133
119
12,7
13,7
EN
loading

Este manual también es adecuado para:

Cesena 9Cesena 11Garda 7Garda 9Garda 11