4.4

Time mode

• If the main display shows °C or °F, press MODE to select TIME MODE.
The main display shows 't' in TIME MODE.
• Press UP or DOWN to adjust the time in steps of 0.1 minute.
• Press POWER to select the power level. Use the guidelines in section 4.8
to determine the correct power setting.
• Press START/STOP to start the heater. The main display shows the time
that remains.
• When the time has elapsed, the heater demagnetises the workpiece, swit-
ches off, and generates an acoustic signal for 10 seconds.
• Press START/STOP to turn the induction heater off.
• Always wear protective gloves and other appropriate protective equip-
ment when removing the hot workpiece. NB: Risk of burning. The workpi-
ece may also be removed using suitable handling equipment.
• Remove the workpiece using proper handling equipment.
• The device is now ready to heat the next workpiece with the same set-
tings.
4.5

Temperature measurement

When the heater is not operating, the temperature of the workpiece can be
measured by pressing MODE and START/STOP at the same time. The LED
on the START/STOP button flashes during temperature measurement. Press
START/STOP to cancel temperature measurement.
4.6

Change of temperature unit

Press MODE and UP at the same time to switch between °C and °F. The tem-
perature unit setting remains the same even after disconnection from mains
power.
4.7

Demagnetisation

According to the „eddy current principle", the work piece is automatically
demagnetised at the end of the heating cycle.