3.3.
Working with the unit
3.3.1.
Press and hold the HOLD key, then press the ON/OFF key to turn on the
scale. The display will show A-ON or A-OFF. Press the ZERO key to turn on
or off the automatic power off:
o
o
Press the UNIT button so the display shows L-ON or L-OFF. Press the ZERO
button to select the automatic backlight function:
o
o
Press the UNIT button, the display will show P-XX. Press the ZERO key to
select from "OFF"/"key"/"con"/"Stb":
o
o
o
o
Press the UNIT key and the display will show J-ON or J-OFF. Press the [ZERO]
key to select ON or OFF:
o
o
3.3.2.
indicator
Press and hold the UNIT and HOLD keys, then press the ON/OFF key to turn
on the scale. The display will show Ani.Sw. Press the UNIT key to enter the
function settings menu - press the ZERO key to select ON or OFF:
o
o
o
Press the HOLD key again to enter the next menu. The display will show
Ani.Kd; press the UNIT key to enter the function setting menu. Then press
the ZERO key to select the anti-shock range of the animal scale from 50,
100, 200, 400 - press the HOLD key to confirm the selection.
Press the HOLD key again to enter the next menu. The display will show
Ani.fd; press the UNIT key to enter the function setting menu. Then press
the ZERO key to select the animal weight filter range from 0.5, 3, 5, 10 -
press the HOLD key to confirm the selection.
Function settings
ON indicates that the auto power off function is enabled
OFF means that the auto power off function is disabled
ON means that the automatic backlight function is activated
OFF means that the automatic backlight function is disabled
"OFF" means that the RS232 function is inactive
"KEY" means that the data is sent when the PRINT key is pressed
"Con" means that the data will be sent continuously
"Stb" means that the data is sent when the reading is stable
ON means to show zero after power on
OFF means showing the value of the load placed after turning on
the power
Setting the operating mode of the
ON stands for animal mode
OFF means normal weighing mode,
press the HOLD key to confirm the selection.