Unpacking
Remove any protective foils and stickers from the soleplate.
Please unwind the lead completely.
Electrical connection
Make sure that the iron voltage (see name plate) and the
line voltage match.
Turn the switches to 0 and the lowest level.
The mains plug should only be inserted into a correctly
installed 230 V ~ 50 Hz socket with earthing contact.
Connected Wattage
The station has a total maximum wattage of 2000 W. With this
connected load a separate supply line protected by a 16 A
household circuit breaker is recommended.
CAUTION: OVERLOAD!
If you use extension leads, these should have a cable
cross-section of at least 1.5 mm
Do not use any multiple sockets, as this device is too
powerful.
Function Switch
0
= OFF
= Cold air
I
= Hot air (1000 W)
II
= Hot air (2000 W)
NOTE:
Select low power, for example, for a small room. If this is not
enough, please switch to the high level.
levels/Heating Power
By regularly switching the radiator on and off, the thermostat
ensures that the desired temperature is maintained.
Highest level
In order to find the ideal thermostat setting, please proceed as
follows:
Turn the thermostat control to the highest level.
As soon as the desired temperature has been reached, turn
the thermostat control slowly down until the radiator turns
itself off. The control lamp on the switch goes off.
The radiator will now automatically stay at the desired
temperature.
CAUTION:
When the device is no longer being used you should always
remove the mains plug.
05_HL3379.indd 21
If you would like to use the device as a ventilator please move
the function switch to the ventilator symbol and turn the tem-
perature control to the highest position.
Turning Off
If you would like to switch the device off, turn the switch to the
lowest level or 0 and then remove the plug from the socket. The
control lamp goes off.
.
2
Model: ..............................................................................HL 3379
Power supply: .....................................................220-240 V, 50 Hz
Power consumption: .................................................1800-2000 W
lowest level
Protection class: ........................................................................... I
Net weight: .........................................................................1,19 kg
This device has been tested according to all relevant current
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance with
the latest safety regulations.
Subject to technical changes without prior notice!
Cold air operation
Overheating Protection
The device is equipped with an overheating protection that
switches the device automatically off in case of overheating.
Shift the function switch to „0" position and pull out plug out
of the socket. Let the device cool down for about 10 minutes
before using it again.
Should the overheating protection shut the device off again
shortly after, there is probably a defect. Switch off the device
again and pull out the plug.
Let the device be checked by an authorized dealer or by our
customer service (or contact your dealer).
Cleaning
AVVISO:
Always remove the mains lead before cleaning!
Wait until the machine has cooled down completely.
Under no circumstances should you immerse the device
in water for cleaning purposes. Otherwise this might result
in an electric shock or fire.
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
Wipe off the radiator with a dry cloth in order to remove dust.
A damp cloth (not wet) can be used to remove stains.
Technical Data