CP 0222
Tightening torques
CP 0222 CHOTBS
CP 0222 CHIT
CP 0222 CHITBS
CP 0222 CHOTBS
Air inlet nipple: 80-100 lbf/ft (108-136 Nm),
A.
use Loctite® 243™ (Loctite is a registered
trademark of Henkel Corporation. 243 is a
trademark of Henkel Corporation.)
B.
Plug: 80-100 lbf/ft (108-136 Nm). After
tightening bend tab washer up against the
plug.
C.
Nut: 75-85 lbf/ft (102-115 Nm).
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
Check that the insertion tool being used has the
♦
correct shank dimension.
Check that the pneumatic machine is getting the
♦
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or
uneven performance.
Check that the compressed air system supplies
♦
the machine with sufficient air pressure to give
full power.
9800 0550 90a | Original instructions
www.CrowderSupply.com • Toll Free: 888-883-5144
CP 0222 CHIT
CP 0222 CHITBS
Safety and operating instructions
♦
Check that the dimension and length of the air
hose are according to the recommendations. See
"Installation".
If there is a risk of freezing, check that the
♦
machine's exhaust ports are not blocked.
If the machine function is still not satisfactory after
♦
this procedure, contact an authorised service
workshop.
Storage
>
Clean the machine properly before storage, in
order to avoid hazard substances. See "Dust and
fume hazard"
>
Pour approximately
1
⁄
2
the air inlet nipple, connect the machine to the
compressed air supply and start it for a few
seconds.
>
Always store the machine in a dry place.
Disposal
A used machine must be treated and disposed of in
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.
oz (5 cl) of oil directly into